Industrial Metal Fabricators, Inc.
 Advantages of the SuperVault MH
     

 

  • 30-YEAR WARRANTY
     
  • ATTRACTIVE:  Both styles have been designed to make an aesthetically pleasing fueling facility.
     
  • EASILY MONITORED:  Monitoring is easily accomplished by checking the monitor tube.
     
  • FULLY LISTED TANK ASSEMBLY:  All SuperVault MH tanks are Mult-Hazard Rated, Insulated and Protected Aboveground Storage Tanks listed to UL 2085 Protected Tank, SwRI 95-03 and 93-01 and UFC Standard A-II-F-1 (formerly known as UFC Standard 79-7) with a 4-Hour Fire Rating.
     
  • BEST INSULATION:
    • MADE OF LIGHTWEIGHT CONCRETE
      Lighter tanks make transportation and installation easier and less costly.
       
    • SOLID CONCRETE INSULATION
      Cannot slough, settle or compact away from the inner tank during normal use or during a fire event insuring maximum protection of fuel and property.  The Special Insulation Formula also helps guard against corrosion of the Steel Primary and Secondary Tanks.
       
    • HEAT TRANSFER TO THE PRIMARY TANK AT AN ABSOLUTE MINIMUM
      No other tank provides a higher level of insulation and fuel security.  Prevents large fuel losses due to evaporation in hot climates.
       
    • MULTI-HAZARD RATED!

  • 4-HOUR FIRE RATING:  The SuperVault MH is the first tank on the market to pass the SwRI 95-03 multi-hazard test, the toughest test for aboveground fuel tanks by a nationally certified testing lab.  Most tanks are single-hazard rated which means they can withstand a hazard (Fire, Bullet, Impact) one time, but then have to be disposed of carefully.  The SuperVault MH has been tested for multiple exposure to fires and other hazards and an extended element exposure test.  This means that if the SuperVault MH experiences a hazard, it may be recertified and kept in service rather than having to be replaced.  No down time.  No fuel loss.  No replacement cost.  The SuperVault MH.  Built to last.
     
  • PUNCTURE RESISTANCE (BALLISTICS):  The  integrity of the primary tank is not endangered by the many bumps and bruises encountered in equipment fueling operations and meets UFC requirements for bullet resistance.
     
  • HIGH IMPACT RESISTANCE:  The SuperVault MH meets the crash test requirements of UFC Standard A-II-F-1 (also called 79-7).  To meet the requirement the tank must be able to withstand the impact of a 12,000 pound battering ram traveling at 10 mph.
     
  • ADDITIONAL SEISMIC RESTRAINTS NOT REQUIRED:  Built-in supports offer integral anchoring capability.
     
  • EXTERNAL DIKING NOT REQUIRED BY UFC:  The SuperVault MH outer tank provides 110% of secondary containment.
     
  • GUARD POSTS NOT REQUIRED BY UFC:  The SuperVault MH tanks meet the impact resistance testing of the Uniform Fire Code.
     
  • AVAILABLE IN TWO STYLES:  Fuel efficient cylindrical or low profile rectangular.