- 30-YEAR WARRANTY
- ATTRACTIVE: Both styles have been designed to make
an aesthetically pleasing fueling facility.
- EASILY MONITORED: Monitoring is easily accomplished
by checking the monitor tube.
- FULLY LISTED TANK ASSEMBLY:
All SuperVault MH tanks
are Mult-Hazard Rated, Insulated and Protected Aboveground Storage
Tanks listed to UL 2085 Protected Tank, SwRI 95-03 and 93-01 and
UFC Standard A-II-F-1 (formerly known as UFC Standard 79-7) with a
4-Hour Fire Rating.
- BEST INSULATION:
- MADE OF LIGHTWEIGHT CONCRETE
Lighter tanks make transportation and installation easier and
less costly.
- SOLID CONCRETE INSULATION
Cannot slough, settle or compact away from the inner tank
during normal use or during a fire event insuring maximum
protection of fuel and property. The Special Insulation
Formula also helps guard against corrosion of the Steel
Primary and Secondary Tanks.
- HEAT TRANSFER TO THE PRIMARY TANK AT AN ABSOLUTE MINIMUM
No other tank provides a higher level of insulation and fuel
security. Prevents large fuel losses due to evaporation
in hot climates.
-
MULTI-HAZARD RATED!
- 4-HOUR FIRE RATING: The SuperVault MH is the first
tank on the market to pass the SwRI 95-03 multi-hazard test, the
toughest test for aboveground fuel tanks by a nationally certified
testing lab. Most tanks are single-hazard rated which means
they can withstand a hazard (Fire, Bullet, Impact) one time, but
then have to be disposed of carefully. The SuperVault MH has
been tested for multiple exposure to fires and other hazards and
an extended element exposure test. This means that if the
SuperVault MH experiences a hazard, it may be recertified and kept
in service rather than having to be replaced. No down
time. No fuel loss. No replacement cost. The
SuperVault MH. Built to last.
- PUNCTURE RESISTANCE (BALLISTICS): The
integrity of the primary tank is not endangered by the many bumps
and bruises encountered in equipment fueling operations and meets
UFC requirements for bullet resistance.
- HIGH IMPACT RESISTANCE: The SuperVault MH meets the
crash test requirements of UFC Standard A-II-F-1 (also called
79-7). To meet the requirement the tank must be able to
withstand the impact of a 12,000 pound battering ram traveling at
10 mph.
- ADDITIONAL SEISMIC RESTRAINTS NOT REQUIRED:
Built-in supports offer integral anchoring capability.
- EXTERNAL DIKING NOT REQUIRED BY UFC: The SuperVault
MH outer tank provides 110% of secondary containment.
- GUARD POSTS NOT REQUIRED BY UFC: The SuperVault MH
tanks meet the impact resistance testing of the Uniform Fire Code.
- AVAILABLE IN TWO STYLES: Fuel efficient
cylindrical
or low profile rectangular.
|
|
|